NFPA 1989 – Standard on Breathing Air Quality for Emergency Services Respiratory Protection – is a critical guideline developed by the National Fire Protection Association (NFPA) to ensure the safety and health of emergency services personnel.

NFPA 1989Standard on Breathing Air Quality for Emergency Services Respiratory Protection – is a critical guideline developed by the National Fire Protection Association (NFPA) to ensure the safety and health of emergency services personnel. This standard specifies the minimum requirements for the quality of breathing air supplied to personnel using atmosphere-supplying respirators during operations in hazardous environments, such as firefighting, rescue missions, hazardous materials incidents, and special operations.


Key Components of NFPA 1989

1. Air Quality Specifications

NFPA 1989 outlines stringent criteria for the composition of compressed breathing air:

  • Oxygen Content: Must be between 19.5% and 23.5% by volume. Levels outside this range can lead to asphyxiation or oxygen toxicity.
  • Carbon Monoxide (CO): Should not exceed 5 parts per million (ppm). CO is a colorless, odorless gas that can cause poisoning at higher concentrations.
  • Carbon Dioxide (CO₂): Should not exceed 1,000 ppm. Elevated CO₂ levels can lead to respiratory issues.
  • Total Volatile Hydrocarbons (TVH): Should not exceed 5 ppm. These compounds can be harmful if inhaled.
  • Oil Mist and Particulates: Should be absent. Oil mist can damage respiratory equipment, and particulates can cause respiratory distress.
  • Nitrogen Content: Should be between 75% and 81% by volume. Nitrogen is an inert gas that dilutes oxygen and prevents combustion.

2. Testing and Maintenance Requirements

  • Quarterly Testing: Compressed breathing air systems must undergo testing every three months by an accredited laboratory to ensure compliance with air quality standards.
  • Post-Maintenance Testing: Air samples must be tested before and after the installation of new air purification filters to verify the system's performance.
  • System Shutdown on Failure: If an air sample fails to meet the specified criteria, the compressor must be taken out of service until corrective actions are taken and the air quality passes retesting.
  • Documentation: Organizations must maintain records of all air quality tests and corrective actions for a minimum of five years.

3. Compressed Breathing Air Systems

  • Compressor Operation: Compressors should be operated for at least 30 minutes each week, including two condensate drain cycles, to maintain system integrity.
  • Cylinder Maintenance: Air stored in steel cylinders must be replaced at least annually to prevent degradation of air quality.
  • System Intake Location: The intake for the air system must be located in a clean, uncontaminated area and must be clearly marked.

Importance of Compliance

Adherence to NFPA 1989 is vital for the health and safety of emergency services personnel. Contaminated breathing air can lead to immediate health risks, such as respiratory distress or equipment failure, and long-term health issues, including impaired lung function and increased cancer risk. Regular testing and maintenance of breathing air systems ensure that personnel are provided with safe, breathable air during operations, thereby enhancing their ability to perform their duties effectively and safely.


Conclusion

NFPA 1989 serves as a comprehensive standard for ensuring the quality of breathing air supplied to emergency services personnel. By specifying rigorous testing, maintenance, and documentation requirements, it helps safeguard the health and safety of those who risk their lives to protect others. Compliance with this standard is not only a regulatory requirement but also a moral imperative to protect the well-being of emergency responders.